| Types of Glass |
Ordinary plate, tempered, wired plate, laminated
Note: The No. 2500 is NOT recommended for protection
of glass areas of less than 1/4 sq. ft |
| Detection Method |
Simultaneous shock and sound |
| Preferred Location |
On same wall as glass |
| Alternative Location |
On wall touching glass's wall |
| Along-Wall Range |
Within 25' of farthest protected glass |
| Indicators |
SOUND (yellow) LED
SHOCK (green) LED
ALARM (red) LED |
| Alarm Memory |
Latching ALARM LED (internally selectable) |
| Input Voltage |
12 VDC nominal (10-16VDC, 3 V P-P ripple max.) |
| Current Drain |
30mA |
| Standby Capability |
Power source should be capable of 4 hrs (minimum) battery standby |
| Alarm Relay Contacts |
SPDT, 1A max. at 24VDC |
| Tamper Switch Output |
SPST contacts, closed with cover in place. Separate terminals for connection
to 24hr loop, if desired |
| Operating Temperature |
32 to 122º F (0 to 50º C) |
| Operating Humidity |
Up to 95% RH (max.) non-condensing |
| Dimensions |
21/16" W x 41/16" H x 11/16"D
52mm x 103mm x 18mm |