| SYSTEM DESCRIPTION
The VISTA-100 is a powerful integrated fire and burglary control that incorporates
advanced technology while simplifying end user operation in even the most demanding
applications. It offers eight partitions in a UL listed Commercial Fire and Burglary
control panel. It supports up to 87 zones using basic hardwired, polling loop and wireless
technologies. It also accommodates indicating circuits, phone lines, keypads, RF receivers
and relays. In addition, the control offers scheduling capabilities and allows defined
operations to be automated. It is available in either 12 or 24 volt models.
PATENTED
GLOBAL POLLING TECHNOLOGY
The VISTA-100 supports up to 79 additional zones using the on-board multiplex circuit.
Current draw can total up to 128mA. Polling loop zones have the following characteristics:
must use RPM (Remote Point Module) devices, supervised by the control panel, individually
assignable to one of eight partitions and individually assignable to bell outputs and/or
aux. relay.
- Speed - global polling allows information from the on-board, two-wire
multiplex circuit to process eight times faster than conventional multiplex systems,
resulting in immediate status and response to off normal conditions
- Distance - 4,000 feet capability without the use of shielded cable
offers installation flexibility
- Power - twice the power capacity of conventional multiplex systems, it
allows the installer to support more devices to meet installation requirements
FIRE DETECTION FEATURES
- Wireless Smoke Detectors - engineering breakthrough allows use of
wireless smoke detectors in full compliance with Commercial Fire Listing UL 864 and meets
the NFPA 72 requirements. Wireless Receiver 5881EH must be used for this feature
- Automatic Smoke Detector Testing - functional testing, from the keypad,
of all multiplex smoke detectors in an automatic sequence, with results stored in the log,
printed on-site or downloaded to a central station. In the past, the installer had to test
each detector individually now testing can be done at the keypad, saving time and
documenting information
- Supports 24V, 3.2A Power for 24V ADA Compliant Fire Notification Appliances -
specify Vista-100-24 Package (includes control and power supply kit)
SYSTEM FEATURES
- Wireless Expansion: It supports up to 87 wireless zones using 5881 or
5881EH Fire type RF Receiver (for use with Q.E.D. control panels only)
Wireless zones have the following characteristics:
- Supervised by control panel for check-in signals (except certain non-supervised
transmitters)
- Tamper protection for 5800 series supervised transmitters
-Individually assignable to one of eight partitions
-Individually assignable to bell outputs and/or aux. relay
- Keypad Macros - accommodates one keypad macro command per
partition which allows simplified keypad commands to control complex events
- Master Console - status of all eight partitions
viewed at a glance. This reduces confusion and provides information immediately
- Faster Downloading - 300-Baud downloading reduces processing
time by two-thirds, saving time and money due to significant reduction in on-line time
- Common Lobby Logic - Allows longer exit time for last arming partition
- Scheduling and Relay Controls - simplifies end user operation by
automating system functions
FALSE ALARM
PREVENTION FEATURES
False alarms are frequently caused by end users during the exit process. This
new control includes several features to help end false alarms due to user error.
- Exit Error Logic - alerts the user and allows for correction in the
event an exit door is left open while keeping the remaining protection points armed; a
unique report is sent to the central station
- Exit Delay Reset - allows for user re-entry without causing an alarm
False alarms are also triggered by application conditions which, when anticipated, can
be accommodated.
- Cross Zoning - allows for combinations of zones to fault before alarm
sounds to avoid sensitive trigger reactions
- Alarm Verification - will double-check an alarm condition before
sounding
8 PARTITIONS
Provides the ability to control 8 separate areas independently, each functioning as if
it had its own separate control.
- A "Common Lobby" partition, which can be programmed to arm automatically when
the last partition that shares the common lobby is armed and disarm when the first
partition that shares the common lobby is disarmed
USER CODES
- Accommodates 128 user codes, all of which can operate any or all
partitions
PERIPHERAL DEVICES
Supports up to 16 addressable devices, which can be any combination of keypads
(6139(R), RF receivers (4281/5881/5881EH), and relay modules (4204/4204CF). Peripheral
Devices have the following characteristics:
- Terminated at the Keypad Port 1 terminals on the control panel (except for the one alpha
keypad, which must be connected to Keypad Port 2)
- Each device is set to an individual address (physically) according to the device's
instructions
- Each device enabled in the system using the Device Programming Mode
KEYPAD PANIC KEYS
- Accommodates three keypad panic keys
KEYPAD MACROS
- Accommodates one keypad macro command per partition, simplifies usage of partitioned
system
NOTIFICATION
APPLIANCE CIRCUIT
- Provides two class B supervised notification outputs on the control panel itself. A
420UCF Relay Module can supply two additional supervised bell outputs
AUXILIARY RELAY
Provides a built-in "Form C" relay which can be used for one of the
following:
- Alarm activation
- Trouble/Supervisory activation
- 4-wire smoke detector reset
- Battery saving feature
OPTIONAL OUTPUT RELAYS
Accommodates the use of 16 relay outputs:
- Can be programmed to activate in response to system events
- Can be programmed to activate using time intervals
- Can be used for additional supervised bell outputs (4204CF only)
- Can be activated manually
- Can be supervised by control panels
- Can each have an alpha descriptor assigned
OPTIONAL
VISTA INTERACTIVE PHONE MODULE
Supports the ADEMCO 4285 VIP Module. This permits access to the security system for the
following:
- Obtain system status information
- Arm and disarm security system
- Control relays
ACCESS CONTROL
If programmed, provides users with a command which activates a relay for two seconds to
open access doors (e.g. lobby door). Each partition can be assigned an access control
relay.
EVENT LOG
Keeps a log of different event types (enabled in programming):
- Stores a total of 224 events
- Can be viewed at the keypad or through the use of V-Link software
- Can be used on a serial printer
SCHEDULING
Provides the following scheduling capabilities:
- Open/Close schedules (for control of arming/disarming and reporting)
- Holiday schedules (allows different time windows for Open/Close schedules)
- Timed Events (for activation of relays, auto-bypassing and unbypassing, auto-arming and
disarming, etc.)
- Access schedules (for limiting system access to users by time)
- End User Output Programming mode (provides 20 timers for relay control)
SPECIFICATIONS
Control Dimensions: 18" H x 14.5" W x
4.3" D
Electrical Specifications:
Primary Power:
- For 12V systems - 1451 transformer with enclosure; rated 18VAC, 72VA
- For 24V systems - 1451-24 transformer with enclosure; rated 30VAC, 188VA
Backup Battery:
- For 12V systems - 12AH min. to 34.4AH max. lead acid battery (gel type)
- For 24V systems - 2-12V, 7AH min. to 17.2 AH max. lead acid battery (gel type)
Alarm Power: 12VDC,1.7 amps max
Aux. Standby Power: 12VDC, 1 amp max
Total Power: Combined auxiliary standby and alarm
currents must not exceed 2.3 amps
Standby Time: 24 hours, or 60 hrs. depending on battery
size and load
Fusing: Battery input, auxiliary and bell power outputs are protected using PTC
circuit protectors. All outputs are power limited
Agency Listings
Burglary: UL 609 Grade A Local Mercantile
Premises and Mercantile Safe and Vault. UL 611/
UL 1610 Grades A, AA Central Station. UL 365
Grades A, AA Police Connect
Fire: UL 864-NFPA 72 Local Central Station and Remote Station
Communications Formats
ADEMCO high speed, ADEMCO 4+2 express, ADEMCO low speed, ADEMCO contact ID, Sescoa,
Radionics low speed
Line Seize: Double Pole
Ringer Equivalence: 0.7B
FCC Registration No.: AC398U-68192-AL-E
6139(R) Remote Keypad Dimensions: 6.25"W x 4.75" H x 1.25" D
Electrical
Voltage Input: 12VDC
Current Drain: 100mA
Interface Wiring for Keypads
Red: 12VDC input (+) auxiliary power
Blue: Not Used
Greed: Data to control panel
Yellow: Data from control panel
Black: Ground and (-) connection from supplemental power supply
ACCESSORY EQUIPMENT
Modules
5140DLM: Dialer module
4146: Keyswitch
5140LED: Communicator status
4100SM: Serial module
Manual Pull Stations
5140MPS-1: Manual fire alarm station, ADA Compliant, key reset, terminal block, gold
contacts
5140MPS-2: Manual fire alarm station, ADA Compliant, allen reset, wire leads
5140MPS-BB: Surface back box for 5140MPS-1 and 5140MPS-2
Consoles
6139 Console: English text - grey
6139R Console: English text - red
Addressable Smoke Detectors
4192CP: Ionization
4192SD: Photoelectronic
4192SDT: Photoelectronic with thermal
Addressable PIR/Motion
4275EX: Multiplex addressable PIR
4278EX/4278EX-SN: Multiplex addressable Quad
PIR
Addressable Glassbreak/shock
7500: Multiplex glassplex glassbreak detector
9500: Multiplex audio and shock detector
Contacts
4194WH: Surface reed contact
Expansion Devices
4190WH: Point expansion module one point
4208: Point expansion module eight points
Compatible Two-Wire Smoke Detectors
2100: Low profile photoelectronic
2100T: Low profile photoelectronic with heat
1100: Low profile ionization
1151: Low profile ionization (uses B110LP base)
2151: Low profile photoelectronic (uses B110LP base)
B110LP: Base for 1151 and 2151
2400: Photoelectronic direct wire
2400TH: Photoelectronic with heat, direct wire
1400: Ionization, direct wire
2451DH: Photoelectronic duct detector with DH400 base
1451DH: Ionization duct detector with DH400 base
Beam Detector
1401: FIRERAY Optical Beam Detector 24VDC
ORDERING INFORMATION
VISTA-100: 12VDC Power 2.3A
VISTA-100-24: 12V Burglary 2.3A 24V Fire 3.2A for Fire
|